Fire alarm annunciator panel is a fire alarm device that can be connected with the fire alarm control panel through the bus, and deal with the data sent by the control panel. fire alarm annunciator panel should be installed in the front room of the elevator, the public walkway, emergency access, or the stairwells. 

The fire alarm annunciator panel, also known as the centralized warning panel or caution advisory panel, is a fire alarm device that can be connected with the fire alarm control panel through the bus, and deal with the data sent by the fire alarm control panel.

When the fire alarm control panel monitors several floors or fire compartments at the same time, you can install an fire alarm annunciator panel on each floor or fire compartment to replace the fire alarm control panel. Usually, the fire alarm annunciator panel includes warning indicators or audible signals to draw the attention of operating personnel to the fire alarm annunciator panel for urgent events.

How to decide on the installation position of the fire alarm annunciator panel? And what position is both suitable for installation and in accordance with the requirements?

​​The installation locations of the fire alarm annunciator panel are as follows:
1.The front room of the elevator
2.The public walkway
3.Emergency access, stairwells, etc.

The installation positions above are convenient for personnel to check and operate.

For the installation height of the fire alarm annunciator panel, you should follow the suggestions below:
1.When installed on the wall, the bottom of the fire alarm annunciator panel should be 1.3m-1.5m from the ground.
2.When installed on the side near the door, the fire alarm annunciator panel should not be less than 0.5m away from the wall.
3.When the fire alarm annunciator panel is operated from its front, the distance should not be less than 1.2m.
4.When installed near the ground, the bottom of the fire alarm annunciator panel should be 0.1-0.2m away from the ground.

ASENWARE offers fire alarm annunciator panels for fire alarm systems, like addressable fire alarm annunciator panels, to meet the different needs of customers, letting the relevant personnel know the location and information of the fire in time.
Related News
Read More >>
Manifold Type FM200 Gas Suppression System Manifold Type FM200 Gas Suppression System
Jun .01.2023
The fire extinguishing agent storage cylinder of the manifold type FM200 gas suppression system is usually placed in the special cylinder room and connected through the pipe network. When a fire occurs, the fire extinguishing agent will be conveyed from the cylinder to the protection area, and will be sprayed through the nozzle to extinguish the fire.
Indoor Fire Hydrant System Maintenance Indoor Fire Hydrant System Maintenance
May .26.2023
Check whether the configuration of the fire hydrant system is complete, including checking whether the static pressure of each fire hydrant meets the design or specification requirements
Gas Fire Suppression System Inspection, Testing and Maintenance Gas Fire Suppression System Inspection, Testing and Maintenance
May .22.2023
The inspection, test and maintenance of the gas fire suppression system is the guarantee to ensure the normal operation of the system when the fire occurs. Specific examples of 8 routine testing tasks.
Fire Sprinkler System Inspection Testing and Maintenance Fire Sprinkler System Inspection Testing and Maintenance
May .11.2023
Fire sprinkler system inspection testing and maintenance is the guarantee for sprinkler system to work normally, can greatly reduce the failure of fire extinguishing